How to install an implant library in exocad, step by step
Which folder from the manufacturer's package needs to be copied, where each one goes, what the config.xml says, and how to fix the most common errors. With real screenshots from exocad DentalCAD 3.3.

Installing a implant library in exocad is one of those tasks that seem trivial until the case is open, the patient has an appointment, and the connection requested by the prescription doesn't appear in any dropdown. In the lab, we install libraries almost every week, so here's the method we follow, with real screenshots from our exocad DentalCAD 3.3.
You will see which folder from the manufacturer's package needs to be copied, where each one goes, what the config.xml and how to fix the most common errors.
What an implant library is (and what it isn't)
An implant library is a folder that the manufacturer prepares for exocad with the geometry of its parts: the implant connection, the Ti-base or interface, the scanbody, and the screw. Thanks to it, exocad knows where the implant is from the scanned scanbody and can design on top with the real part.
It's advisable not to mix it with two other things also called "library":
- Tooth libraries: these are anatomies for designing crowns and bridges. They are installed in another folder and have their own guide: how to install a tooth library in exocad.
- Analogs for Model Creator: they are used to print the model with the analog's slot. They usually come in the same manufacturer's package, but go to a different folder (we'll see it below).
Before starting: get the official manufacturer's library
Each implant company publishes its libraries for exocad on its website, usually in a "digital libraries" section. Some are downloaded directly; others ask for a form and send them to you by mail. Always download the official library and distrust copies circulating in groups: a library with erroneous measurements does not give an error, it simply makes the fit in the mouth not what you expected.
When unzipping the package, see how it is organized. In the screenshot you have Avinent's (version 9.2): it separates what goes to the implant library from what goes to Model Creator.

Step by step: install the implant library manually
This is the method that works with any manufacturer, whether or not it is in exocad's online catalog.
- Close exocad completely. exocad reads libraries when it starts, so close all DentalCAD windows you have open. Save anything you are designing first.
- Open the implant folder of the package. Inside you will see a folder for each system and part type. Avinent, for example, brings 46: direct to implant, Ti-base, Ti-base with angle correction, and millable Ti-base for each compatible brand.
- Choose only the folder you need. Look at the prescription to see which system, connection, and part the case requires, and keep that folder. There's no need to copy the entire package.
- Copy it inside
DentalCADApp\library\implant\, in the folder where exocad is installed. In our case it isC:\exocad-DentalCAD3.3-SR2-2026-10-27\DentalCADApp\library\implant\. - Check that the
config.xmlremains at the first level. Insideimplantthere must be one folder per library and, inside each one, theconfig.xmlnext to the parts. If a folder ended up inside another when copying, exocad will not see it. - Open exocad. The first time it takes a little longer: the message "Please wait while local implant library cache is built" appears, which only shows up after installing or updating libraries.
- Look for it in the implant step. In 3.3, implant selection is a catalog with a search engine: type the brand and choose library, type, and subtype. The name you will see is the one the manufacturer puts in the
config.xml, not the folder's.

Install only the folder you are going to use. With the entire package, the dropdowns and the search engine fill up with almost identical options, and it's easier to choose the wrong one in a hurry. Save the complete package separately: what you don't install today, you take from there when a case that requires it comes up.

Don't know where exocad is installed? Right-click on the DentalCAD shortcut and choose "Open file location". It takes you to DentalCADApp\bin; go up one level and there it is library.
What's inside an exocad implant library
When you open an already installed library, you will see three types of files:
.sdfa: the parts (implant, interface, scanbody, screw) in exocad format..partInfo: the information for each part.config.xml: the file that links everything and tells exocad which part is which.

If you open the config.xml with Notepad (read-only), there are four lines that save you many doubts:
| Tag | What it's for |
|---|---|
DisplayInformation | The name you will see in exocad when searching for the library. Here, "Alpha-Bio Tec® – Alpha Base CS". |
Keyword | The internal identifier of the library. There cannot be two libraries with the same one. |
Supplier | The manufacturer. |
ImplantFilename y ScrewFilename | Which .sdfa files it uses as implant and as screw. |

Do not edit the config.xml of an official library to "fix" something without saving a copy of the original first. A small change can cause exocad to stop loading the entire library or, worse, to load it with a different position than the real one.
The analogs go in another folder: Model Creator
If you are also going to print the model with analogs, the package usually brings a separate folder for Model Creator. Those libraries do not go in implant, but in DentalCADApp\library\modelcreator\implants\. The procedure is the same: exocad closed, only that company's folder and check that the config.xml remains at the first level.

Install it from exocad 3.3 with "Download more libraries..."
Since 3.3 there is another way for libraries that are in exocad's online catalog. In the list of libraries in the implant step, the option "Download more libraries..." appears, which opens the catalog in the browser. The download and copy are done by the exocad Library Manager, which also warns you if you already had an older version and lets you update or skip it. Manufacturers that work this way appear in the exocad implant libraries page.
When finished, the program itself reminds you that exocad needs to be restarted for the new library to load. For what is not in that catalog (many manufacturers publish their package only on their website), the manual method above is still the good one.
In the library list you can mark the ones you use as favorites and hide the rest of the dropdown. With 150 libraries installed, as we have, it's the difference between finding the right one in two seconds or two minutes.
Typical errors when installing an implant library in exocad
These are the warnings we see most often and what is behind each one:
| What you see | Why it happens | How to fix it |
|---|---|---|
| The library does not appear | The folder ended up inside another, or exocad was open when copying | Leave the config.xml at the first level of implant and restart exocad |
| «Implant library loading error due to duplicate folder name» | The same library is installed twice, for example an old version and a new one | Leave only one. The other, outside of library\implant (renaming it inside is not enough) |
| Warning that the software path is too long | exocad is installed too deep in folders or with very long names | Ask your distributor to leave exocad near the root of the disk, for example in C:\ |
| «The implant library version previously used is not installed on this computer» | The case was designed on another PC with another version of the library | Install the same version on all lab computers |
| Error that market regulations require a valid library signature | The library is not official or has been modified | Reinstall the official manufacturer's library |
Our protocol with exocad in the laboratory
What has saved us the most trouble is not an exocad trick, but order:
- The original zip is always archived in a shared folder by manufacturer, as it arrives. The Downloads folder is for a single PC and does not sync.
- Each download is recorded in a history: date, manufacturer, package version, where it came from and on which computers it is installed.
- Same version on all PCs. If a case is opened on another computer, the library must be exactly the same.
- A library that we modify is saved separately, with the change in the folder name, so as never to confuse it with the official one.
If you are learning to design on implants, in our online exocad course we see this complete workflow with real cases: from choosing the correct library to registering the scanbody and designing the structure.
Frequently Asked Questions about the implant library in exocad
Do I have to restart exocad after installing a library?
Yes. exocad loads libraries on startup, so with the program open you won't see the new one. After copying it, close all DentalCAD windows and reopen.
Where is the exocad library folder?
Inside the installation folder, in DentalCADApp\library. Implant libraries go in library\implant and the Model Creator analogs in library\modelcreator\implants.
Do I have to install all the folders in the package?
No. Copy only the system and part that your case uses. Save the rest with the original zip in case you need it later.
How do I remove a library I no longer use?
With exocad closed, take its folder out of library\implant and save it somewhere else instead of deleting it. If an old case needs it, you can put it back.
Is the implant library the same as the teeth library?
No. The implant one brings the manufacturer's parts (connection, Ti-base, scanbody); the teeth one brings anatomies for designing. If you are looking for teeth, we have our own tooth libraries for Exocad.
Equipo de Prodecad Academy
Técnicos dentales que diseñan en exocad todos los días para laboratorios y clínicas. Cada truco de este blog se ha hecho y comprobado en exocad antes de publicarlo; las capturas son de nuestro propio programa.
Academia Prodecad
Diseña en exocad con criterio, no a base de tutoriales sueltos
Todo el flujo, de cero a experto, explicado desde el trabajo real de un laboratorio. Entra, mira el primer módulo y decide después.
- 5 cursos, de cero a experto
- Más de 230 lecciones
- Corrección de casos en directo cada martes