Exocad analogs for Model Creator: how to install them and what they are for
Where Model Creator analogs are installed, how exocad chooses them for each implant, what their config.xml says, and how the clearance of the printed model is adjusted. With real screenshots from exocad DentalCAD 3.3.

The analogs in Model Creator are the piece that converts a printed model into a working model for implants: without them, exocad prints the gum and teeth, but does not leave the housing where the implant replica goes. For it to work, the analog library must be installed, be the one corresponding to your implant, and leave the exact replica in the resin.
Aquí tienes qué hacen los análogos de exocad en el modelo, dónde se instalan, cómo los elige el programa, cómo se ajusta la holgura y qué significan los avisos que más salen. Con capturas reales de exocad DentalCAD 3.3.
What exocad analogs do in the printed model
The lab analog is a metallic replica of the implant (or abutment, if working on multiunit) that is inserted into the model. With it, you screw the Ti-base or the structure, check seating, contacts and emergence, and deliver the work tested on the actual implant position.
In plaster, the analog is placed manually by the technician. In a printed model, the design places it: Model Creator takes the position of each implant, which came from the scanbody registration, and opens the exact hole in the model for the replica to enter there and nowhere else. For this, it needs two geometries for each analog, which come in a separate library from the implant library:
- The analog (
ModelLabAnalogFile): the piece as is, the one you see on screen. - The retention (
ModelLabAnalogRetentionFile, «Analog retention» in exocad): the shape of the hole. Some manufacturers call it «sleeve» or «hole» in the file name.
If that library is missing, exocad warns in the «Analogs» step, and if you continue without it, the housing will not be created in those teeth.
Where they are installed: the modelcreator\implants folder
Exocad analog libraries do not go with implant libraries (library\implant), but in DentalCADApp\library\modelcreator\implants, inside the folder where exocad is installed.

Inside implants there is one folder per library with its config.xml at the first level, like the demo libraries that exocad brings. It's the same rule as with the implant libraries in exocad.
Before starting: the manufacturer's analog library
Analogs for Model Creator are published by each implant manufacturer. Always get them from the manufacturer's official website or through your distributor. Sometimes they come in the same package as the implant libraries, in a separate folder; other times, in their own package, and some manufacturers send them by mail after a form.
The Avinent package (version 9.2), for example, brings 16 analog libraries in «01_Modelcreator (ESP)», one per compatible brand:

Before choosing, a rule: the analog library must be from the same manufacturer as the implant library you design with. If the crown goes on an Avinent Ti-base for Nobel connection, the analog is Avinent's for Nobel, not Nobel Biocare's.
Step by step: installing analogs in exocad's Model Creator
- Close DentalCAD. Save what you are designing before touching the folder
library, as with any library. - Look for the analog folder in the package. It is usually called «Modelcreator» or has «Analogs» in the name. If the package already includes the exocad path (
modelcreator\implants\…), its folders are copiedimplants, not the entire package. - Choose only the library for your case. The one from the manufacturer and the connection requested by the prescription.
- Copy it to
library\modelcreator\implants. Check that theconfig.xmlremains inside, next to the STLs or sdfa. - Let exocad choose. In the «Analogs» step of Model Creator, exocad automatically searches for the analog compatible with each implant. If there are several, it asks you which one to use for each tooth.
- Review the model before exporting it. Each implant, with its housing, and no analog showing through the socket or sides.


What the config.xml of an analog library says
Opened with Notepad (read-only), the config.xml explains almost all problems with exocad analogs. This is Ticare's for its InHex STD connection:

| Tag | What it's for |
|---|---|
CompatibleImplants | Which implants the analog is valid for. Each line: implant library, type and subtype, separated by «:». An asterisk is valid for all. |
ModelLabAnalogFile y ModelLabAnalogRetentionFile | The analog and its retention, the shape of the hole. |
OffsetMethod | How compensation is applied. In all the ones we have installed that define it, RadialOffset: clearance around the analog. |
OffsetMinimum y OffsetMaximum | Its margin. In this one, from −0.2 to 0.2 mm. |
OffsetProvided | The compensation that the library brings. In this one, 0.05 mm. |
One of the lines of CompatibleImplants is 000_TC_InHex_TITANIUM : STD : TC11_NOROT_INHEX_STD: library "000_TC_InHex_TITANIUM" (its folder in library\implant), type "STD" and subtype "TC11_NOROT_INHEX_STD". If the implant library you designed with is not in that list, exocad will not find the analog even if it is installed.
Hence the rule of the same manufacturer: Avinent's analog library for Nobel only names the four Avinent libraries for that connection (direct, Ti Base, millable, and angle correction), in more than 1,200 lines, and Nobel Biocare's conical connection library only names Nobel Biocare libraries.
Do not "fix" an analog that does not appear by adding lines to CompatibleImplants by eye. If it's not for your system, the model comes out with a gap that is not for your replica, and that doesn't give an error: you discover it when the replica doesn't fit or doesn't seat. Ask the manufacturer for the correct library.
Analog clearance in Model Creator
Between a replica that fits tightly and one that wiggles, only the clearance changes. exocad controls it in two places: in the library, with the values Offset… that we just saw, and in the model design. In the "Model design without plate" step, "Implants" tab, "Implant model" group, are "Horizontal compensation" (by default, 0.05 mm, between −0.2 and 0.2) and "Vertical compensation" (by default, 0, with the same margin).
According to the exocad wiki on model design, that compensation can only be changed if the analog library has it configured. The same page recommends adjusting the "Width" of "Model analog supports" (by default, 1.0 mm) to ensure a minimum of material around the analog.
More compensation means more clearance: the replica fits looser. The correct value depends on how your printer and your resin print, which is why some manufacturers provide a test piece. Ticare includes a "CALIBRATION BLOCK" with a three-step README: print the block, test with a replica which of its three settings (0.98, 1, or 1.02) convinces you, and adjust RadialOffset to that measurement. Galimplant sends a "Replicas Verification Probe" for the same purpose.
Change the compensation little by little, print a test, and note the value that works with each printer and each resin. There are labs that work with compensation at 0 because their printers are calibrated and, with clearance, the replica fits loosely. If you are still choosing equipment, you have our comparison of dental 3D printers.
Typical errors with analogs in exocad
Model Creator warnings about analogs, with the exact text from exocad 3.3 in Spanish:
| What you see | Why it happens | How to fix it |
|---|---|---|
| "Info: Some analog models could not be loaded." | There is no analog library for that implant, or it doesn't name it in CompatibleImplants | Install the one from the same manufacturer as the implants. With "Ignore", the model comes out without housing in those teeth |
| "For the selected model analog, several model analogs are available." | There is more than one compatible analog among the installed libraries | Choose the one for your physical replica and, if there's an extra library, remove it from implants |
| "Some analogs are positioned too close to the model limit." | The analogs would go through the base or come out of the model | Choose "Model realignment" and reposition the model |
| "Error: It is not possible to apply one of the analogs to the model." | exocad cannot open the housing with that scan shape or emergence profile | Smooth the scan near the implants or change the curves of the emergence profiles |
| "The analog configuration file format has changed." | Library in the old format, which exocad will stop supporting | Ask the manufacturer or your distributor for the current version |
How we do it with exocad in the lab
- The original package is archived as it arrives, in a folder shared by manufacturer and with the analogs separate from the implant libraries. This way, when a case with a model comes in, it's seen in seconds if we already have those from that manufacturer.
- Only the analogs from the case's manufacturer are installed, and only if the case might need a model. No installing all 16 libraries from a package "just in case".
- Each installation is noted: date, manufacturer, package, and which exact folder was installed on each computer.
- Same version on all PCs, so that a case turns out the same no matter who finishes it.
If you want to master this workflow from start to finish, in our exocad course there is a fixed-on-implant module and another for digital models for printing, including the model with analog and removable gingiva.
Frequently Asked Questions about exocad.
Where is the exocad analog folder?
In the installation folder, in DentalCADApp\library\modelcreator\implants, one folder per library with its config.xml.
Why does my printed model come out without the analog hole?
Because exocad did not find a compatible analog and proceeded with "Ignore". Install the analog library from the same manufacturer as the implants and return to the "Analogs" step.
What compensation do I set for the analogs?
exocad suggests 0.05 mm of horizontal compensation, but the correct value is given by a printed test with your printer and your resin. If the manufacturer includes a calibration block, print it before the first case.
Equipo de Prodecad Academy
Técnicos dentales que diseñan en exocad todos los días para laboratorios y clínicas. Cada truco de este blog se ha hecho y comprobado en exocad antes de publicarlo; las capturas son de nuestro propio programa.
Academia Prodecad
Diseña en exocad con criterio, no a base de tutoriales sueltos
Todo el flujo, de cero a experto, explicado desde el trabajo real de un laboratorio. Entra, mira el primer módulo y decide después.
- 5 cursos, de cero a experto
- Más de 230 lecciones
- Corrección de casos en directo cada martes